Home Magnetic flux leakage detector
Ultra-high definition magnetic flux leakage internal detector
Product Introduction
Function:Ultra high definition detection capability exceeding 10m/s, accurate quantification of pipeline defect characteristics.
Configuration:Power section, detection section, mileage section, battery, low-frequency transmitter, receiver, inertial navigation system (optional), and internal stress detection (optional).
Product characteristics
- 01Self developed, domestic full speed ultra-high definition three-axis magnetic flux leakage internal detection.
- 02Fast detection capability exceeding 10m/s to improve the adaptability of natural gas pipeline.
- 03Axial sampling spacing is less than 0.5mm.
- 04The circumferential channel of the pipeline is completely covered without omission, with zero clearance.
- 05Redundant dual fuse independent sensor.
Main Technical Parameters
Model |
MI168 |
MI219 |
MI273 |
MI323 |
MI508 |
MI1016 |
|
Number of section |
4 |
3 |
2 |
1 |
|||
(mm)Detector length |
1540 |
1410 |
1680 |
1700 |
1850 |
1950 |
|
(kg)Detector weight |
56 |
82.5 |
161 |
200 |
450 |
2600 |
|
Wall thickness |
≤10 |
≤10 |
≤12 |
≤12 |
≤14 |
≤20 |
|
Capability to move through bent pipes |
2.5D |
2.5D |
2.5D |
1.5D |
1.5D |
1.5D |
|
Capability to move through pipe deformation sections |
15% |
15% |
15% |
15% |
15% |
20% |
|
Working hours |
24 |
48 |
96 |
96 |
96 |
48 |
|
Number of corrosion channels |
>504 |
>720 |
>864 |
>1044 |
>3456 |
>7056 |
|
(km) Maximum one time detection mileage |
200(Adjustable) |
||||||
Detector configuration |
Power section, detection section, mileage section |
||||||
Temperature |
-20~80℃ |
||||||
Speed |
≤10m/s |
||||||
Pressure |
≤12MPa |
||||||
Sampling distance |
<0.5mm |
||||||
(mm) Circumferential spacing |
<2 |
0 |
|||||
Cup interference |
1~5% |
||||||
Number of mileage channels |
3 |
our cases
I want to place an order
-
Name*
-
Tel*
-
Email*
-
Msg*